share this post

on this page

A battery business case usually looks watertight in the proposal. Take one with 500 kWh of storage, a payback period of around six years and a tidy chart on page three. Then the proposal reaches your client’s finance director, who asks two questions. Where do those six years come from? And what happens if energy prices move differently?

A technical proposal shows that the battery works. The finance director wants to know how certain the returns are, what the battery costs over its whole life and what it costs to do nothing. Until those answers are on the table, the proposal stays in the pile.

If you sell batteries to businesses as an installer or energy consultant, you’ll recognise this. In five steps, you can build a business case that does answer those questions.

TL;DR

You build a battery business case in five steps: map every value stream, calculate them together, set every lifetime cost against them, split base case and upside, and summarise it on one page. A battery earns money in several ways at once, and that’s exactly why the case easily turns out too optimistic.

  • Start with every value stream: peak reduction, growth within the connection, self-consumption of solar power, price spreads and tax relief. Peak reduction is the easiest to make firm: in the Netherlands, one quarter-hour over contracted capacity can cost more than €4,650 outside a congested area.
  • Calculate the value streams together. The same kilowatt-hour can’t absorb a peak and be traded at the same moment.
  • Set every lifetime cost against them: installation, control, maintenance, insurance, fire safety and wear.
  • Split the case into a base case and an upside from trading, and show what doing nothing costs.
  • At Van Ommen, Hollander Techniek’s simulation showed that solar panels only solved the summer. The battery covered the winter, and with it the new production hall.

A case the finance director can check for themselves beats a case with a nicer number.

Why battery proposals stall with the finance director

To you, a battery is a technical fix for a peak problem. To your client, it’s an investment competing with a new forklift fleet, an extra loading dock or a canteen refurbishment. The finance director compares those options on return and risk, and a single payback figure says little about the second.

The finance director rarely decides alone, either. The technical or facilities manager looks at continuity, space on site and fire safety. A sustainability manager wants to know what the battery does for the CO₂ figures in the annual report. They all read the same business case, each with a different question. The five steps below make sure all three find their answer.

Step 1: which value streams belong in a battery business case?

A battery business case starts with the value streams: the ways the battery earns money or avoids costs. A commercial battery rarely earns in just one way, and which lines count depends on your client’s connection, contract and load profile. These are the value streams that can count:

  • Peak reduction. On a large commercial connection, network charges depend heavily on contracted capacity and the highest quarter-hour peak each month. A battery that absorbs peaks brings that cost down and prevents exceeding contracted capacity.

  • Growth within the existing connection. If your client can add a new hall, a charging depot or an electric production line without a grid upgrade, that’s often where most of the investment’s value sits. It just doesn’t show up on the energy bill. You make that value visible in the scenario where the client does nothing.
  • Self-consumption of solar power. Without a battery, surplus generation at midday goes back to the grid at a low or even negative price. With storage, the client uses that power later.
  • Price spreads. With a dynamic energy contract, the battery charges in cheap hours and discharges when power is expensive. Depending on the contract and the site, trading on the imbalance market can come on top.
  • Agreements with the grid operator. In congested areas, flexibility can earn extra through congestion management.

  • Tax relief. Under the Dutch Energy Investment Allowance (EIA), a business investing in 2026 can deduct 40% of the investment costs from taxable profit. Battery systems that store sustainably generated electricity were on the list in 2025, and that year businesses invested around €1 billion in batteries through the EIA. RVO updates the list every year, so check the Energielijst for the year your client invests.

A distribution centre with a charging depot has a different mix from a cold store or a metalworking plant with a spot welding line. So calculate on that one site’s quarter-hour data, over at least a year. Our earlier blog on energy simulation explains which data to collect from your client and why annual averages are too coarse.

Step 2: why calculate the value streams together?

You calculate a battery’s value streams together because they share the same capacity. Add them up as separate rows in a spreadsheet and you’ll almost always count twice. If 300 kWh has to be ready to absorb the afternoon peak, that same 300 kWh can’t be offered on the imbalance market at that moment. In practice you divide capacity across the day, and that split decides what each value stream really earns.

Wear works the same way. Every charge and discharge cycle uses up battery life. A strategy that cycles the battery three times a day for trading can earn more than one cycle for peak reduction, but it also brings the end of the warranty closer. Put the number of cycles in your calculation next to the supplier’s warranty terms. If they don’t fit, neither does your payback period.

You solve both problems with an energy simulation at quarter-hour level, with one battery that has to choose every time. You then see which share of the capacity goes to which value stream, and how many cycles that costs per year. Model it with the same control logic that will actually run the battery, or you’re calculating a strategy nobody will carry out.

Generated with AI

Step 3: which lifetime costs belong in the case?

A complete battery business case sets every cost over the battery’s whole life against the revenue. A payback period says nothing about what happens once the investment has been recovered. Besides the battery and inverters, the costs include installation, any changes to the switchgear, control, maintenance and insurance. Include the wear from charge cycles as well: after a number of years the battery delivers less capacity, and so less revenue.

Fire safety belongs in the case from the start. In the Netherlands, PGS 37-1 is the guideline for energy storage systems with lithium batteries, adopted in December 2023, and municipalities can use it in their rules for siting. Requirements for distances, layout or extinguishing systems can affect both cost and planning. Map them early, so the technical manager doesn’t turn up halfway through with a new cost line.

With revenue and costs over the full lifetime, you can show the net present value alongside the payback period. That lets the finance director compare the battery with the other investments on the list, using the measure they already use for those.

Step 4: how do you show uncertainty?

You show uncertainty by splitting the business case into a base case and an upside, with a sensitivity analysis and a scenario where the client does nothing. To make the payback period look as short as possible, it’s tempting to put all revenue on one pile, trading included. That revenue depends on price spreads that can differ a lot from one year to the next. A finance director knows this, and so treats the whole number with suspicion.

The base case holds what depends least on the market: peak reduction, self-consumption of solar power and the tax relief. The upside holds price spreads and trading, and only uses the capacity left over after the base case. That stops the same kilowatt-hour from counting in both layers. If the investment already pays off in the base case, that’s your strongest argument.

Value streams per layer of the business case
Depends on
Place in the business case
Peak reduction
Load profile and contracted capacity
Base case
Self-consumption of solar power
Generation, consumption and feed-in price
Base case
Tax relief (Dutch EIA)
Energielijst for the investment year
Base case
Price spreads
Spread in hourly prices under a dynamic contract
Upside
Imbalance market trading
Market prices and capacity left after the base case
Upside
Agreements with the grid operator
Fixed fee or payment per call
Base case or upside, depending on the agreement
Growth within the connection
Expansion plans and waiting time for a grid upgrade
Scenario where the client does nothing
Indicative split. The allocation differs per site, contract and agreement with the grid operator.

Add a sensitivity analysis on the two assumptions that matter most, for example consumption growing by 20% or price spreads halving. And put the do-nothing scenario next to it. This is also where the growth the battery enables belongs: the cost of a new hall that opens a few years later, or of a place in the queue for a grid upgrade. The penalties for exceeding capacity that continue without a battery count here too.

Step 5: what goes on the one page for the board?

A twenty-tab spreadsheet rarely convinces a board. So put the business case on one page, with these elements:

  • The total investment and annual costs over the lifetime
  • Annual revenue per value stream, with base case and upside shown separately
  • Payback period and net present value in both scenarios, plus the range under the two key assumptions
  • What it costs to do nothing
  • The technical preconditions: space on site, fire safety and connection capacity
  • The effect on CO₂ figures, for the sustainability report

The model itself goes along as an appendix. Anyone who wants to check the numbers can. Everyone else reads one page.

How did Hollander Techniek build the business case for Van Ommen?

Van Ommen, a metalworking company in Beekbergen, wanted to build a new production hall. Its contracted capacity was maxed out, the regional grid was full, and applying for more capacity wasn’t an option. Bastian Hoonhorst, advisor at installation partner Hollander Techniek, therefore started by simulating the new situation in a digital twin.

“We mapped out the customer’s needs, linked the required power to it and put that information into the software,” says Hoonhorst. The result was clear: “The current energy profile and the simulated future consumption created a peak that was too high for the grid contract.”

Adding solar panels to the model partly solved that, but only in summer. For the rest of the year there was still a shortfall, and the new spot welding line would cause significant power peaks on exactly the darkest days. The battery Hollander Techniek then supplied absorbs those winter peaks, and Tibo EMS controls it. The new hall has been built, and Van Ommen can keep growing at its existing site.

What this example shows is the order of the reasoning. First the problem in the client’s own load profile, then why solar alone wasn’t enough, and only then the battery. That way the simulation shows why this particular investment is needed, which is exactly the question a finance director asks. In terms of the five steps: the biggest value stream was growth (step 1), and the simulation showed which combination of assets made that growth possible (step 2). Read the full story in the Van Ommen case study, or at Hollander Techniek on its own website (in Dutch).

Why does control belong in the business case?

Control belongs in the business case because a battery’s revenue depends on what it does at every moment. Every battery business case assumes the battery does the right thing at the right time. Absorb the peak at four in the afternoon, charge cheaply overnight, hold enough charge for the spot welding line on a dark winter day. That only happens if the control system actually makes those choices.

A simple rule such as “charge on surplus, discharge on a peak” can’t. It doesn’t know what tomorrow’s price will do or when the next peak is coming, so it can’t hold capacity back. A battery running on that kind of controller earns only part of the revenue in your calculation, and your client only notices at the first annual settlement. How an EMS and a battery work together is covered in EMS and battery storage.

Tibo EMS, our Energy Management System, recalculates a control schedule for the next 48 hours every five minutes, based on energy prices, weather forecasts and the site’s load profile. Simulation and EMS run on the same model. The scenario you showed the finance director is therefore the scenario the control system runs after installation, without setting everything up again. How that handover works is explained in from simulation to a working EMS.

To be fair, a simulation calculates on historical data. The result is a well-founded indication rather than a guarantee, and that’s how you should present it. After go-live, you as the partner can see in the EMS how the site performs and which alerts come in, so you can adjust when your client’s consumption changes. For what else comes with adding energy control to your offer, read what installers need to know about flexible energy control.

Want to build cases like this for your clients?

Tibo Energy is a Dutch software company based in Eindhoven that gives large energy users certainty over their energy: a plan validated before they spend, running automatically once it’s live. Tibo works with installers and energy consultants as partners. You keep the client relationship, the advice and the installation. We provide the simulation software you run your scenarios in, training through our Kickstarter programme, support from our implementation engineers on your first projects, and Tibo EMS for control after installation. For every EMS licence you sell, you receive a kickback.

Curious what your next battery case looks like when you build it this way? The partner page explains how the partnership works and lets you book a call about your next project.

Frequently asked questions

A battery business case is a calculation that shows what a battery earns a business over its life compared with what it costs. You build one in five steps. Map every value stream, calculate them together on the site’s quarter-hour data, set every lifetime cost against them, split the case into a base case and an upside, and summarise it on one page for the board.

A battery business case usually includes peak reduction within contracted capacity, growth without a grid upgrade, self-consumption of solar power, price spreads under a dynamic contract and, in the Netherlands, tax relief through the EIA. Depending on the site, imbalance market trading and agreements with the grid operator can come on top.

A battery business case includes the battery and inverters, installation, any changes to the switchgear, control, maintenance and insurance. Also account for wear, because capacity drops after a number of years, and for the requirements fire safety places on the installation.

The payback period of a commercial battery varies a lot from site to site. It depends on the load profile, the connection, the energy contract and which value streams count. Calculate it on the site’s quarter-hour data and present a base case with a range rather than a single number. If the battery already pays off on predictable revenue such as peak reduction and self-consumption of solar power, the case is at its strongest.

Battery systems that store sustainably generated electricity were on the Energielijst in 2025. For investments in 2026, the deduction is 40% of the investment costs. RVO updates the list every year, so always check the Energielijst for the year the investment is made.

Partners run scenarios in our simulation software, on their client’s data. On your first projects, our implementation engineers support you. After installation, Tibo EMS controls the battery using the same model.

follow us

Don't miss the next spark.

Subscribe and catch the latest in energy management.